Accessories and components
Accessories and components
End terminations, connectors, and much more for trace heating
Our extensive range of accessories and components for electrical trace heating, such as end terminations, connectors or connection sets, enables the smooth, custom implementation of almost any trace heating project. Our experts would be happy to advise you.
Product
for heating tapes
Clamps
Surroundings
Download Technology
Download Approval
JBS-100-xxx
BTV
QTVR
XTVR
HTV
VPL
incl. Connection Kit
10 mm²
IP 66
-50 … +40 (+56)°C
JBM-100-xxx
BTV
QTVR
XTVR
HTV
VPL
incl. Connection Kit
10 mm²
IP 66
-50 … +40 (+56)°C
JBU-100-xxx
BTV
QTVR
XTVR
HTV
VPL
for Connection kits (not included)
C25-100
C25-21
CCON25-100
10 mm²
IP 66
-50 … +40 (+56)°C
JB-EX-20-xxx
FMT
FHT
PI
MI (M20)
for connection kits
M20
Main cable
M25 (EX)
10 mm²
IP 66
-55 … +55 °C
JB-EX-21
FMT
FHT
PI
MI (M20)
for
Connection kits
M20 (EX)
Main cable
M25 (EX)
10 mm²
IP 66
-55 … +55 °C
JB-EX-21/35MM2
PI
MI (M20)
for
Connection kits
M20 (EX)
Main cable
M40 (EX)
35 mm²
IP 66
-55 … +55 °C
JB-EX-40 EP
MI (M25)
for
Connection kits
M25 (EX)
Main cable
M25 (EX)
10 mm²
IP 66
-55 … +55 °C
JB-EX-41 EP
MI (M25)
for
Connection kits
M25 (EX)
Main cable
M25 (EX)
10 mm²
IP 66
-55 … +55 °C
JB-EX-42 EP
MI (M25)
for
Connection kits
M25 (EX)
Main cable
M40 (EX)
35 mm²
IP 66
-55 … +55 °C
JB-82
all
for Connection kits
M20
M25
10 mm²
IP 66
-35 … +115 °C
80 °C
Product
for heating tapes
Clamps
Surroundings
Download Technology
Download Approval
C25-100
Cold applied connection kit
BTV
QTVR
XTVR
HTV
VPL
M25
IP 66
-55 … -40°C Impact
resistance 4 joules
-40 … +110°C Impact
resistance 7 joules
C25-21
Heat-shrink connection kit
BTV
QTVR
XTVR
HTV
VPL
M25
IP 66
-55 … -40°C Impact
resistance 4 joules
-40 … +110°C Impact
resistance 7 joules
CCON2x-C
Protective tube
Heating pipes cold pipes
17 mm
(M20)
23 mm
M25
-40 … +135/150 °C
-200 … +260 °C
C25-100-METAL
Cold applied connection kit
BTV
QTVR
XTVR
HTV
VPL
M25
3/4 Inch
IP 68
-60 … +180 °C
C-150-E
Cold applied connection kit
BTV
QTVR
XTVR
IP 66
-50 … +215 °C
CS-150-UNI-PI
Cold applied connection kit
Single conductor-PI
IP 66
-50 … +150/180 °C
CS-150-xx-PI
Sealing technique
Single conductor-PI
IP 65
+200 (260) °C
CS20-2,5-PI-NH
Heat-shrink connection kit
Single conductor-PI
M20
-50 … +205 °C
Product
for heating tapes
Clamps
Surroundings
Download Technology
Download Approval
S-150
Cold applied connection kit
BTV
QTVR
XTVR
IP 66
-50 … +215 °C
T-100
(Cold applied connection)
BTV
QTVR
XTVR
HTV
VPL
IP 66
-50 … +56 °C
Product
for heating tapes
Clamps
Surroundings
Download Technology
Download Approval
E-100-E
Cold applied connection kit
BTV
QTVR
XTVR
HTV
VPL
IP 66
-50 … +56 °C
E-100-L-E
Cold applied connection kit
BTV
QTVR
XTVR
HTV
VPL
IP 66
-40 … +40°C
E-150
Cold applied connection kit
BTV
QTVR
XTVR
IP 66
-50 … +215 °C
Product
for heating tapes
Clamps
Surroundings
Download Technology
Download Approval
Product
for heating tapes
Download Technology
Download Approval
Raychem accessories
Raychem accessories
General accessories
Mounting bracket
Identification stickers
Adhesive tapes
Fixing material
Clamps
Screw fittings
Adapters
Power supply units
PI-TOOL-SET-XX
Toolbox with crimping tool, crimp inserts and ferrules for single-conductor PI heating cables
Better performance with our products
High-quality accessories for trace heating
The perfect selection of individual components for electrical trace heating is essential for reliable and secure operation. Our product range includes components to configure trace heating for both large industrial plants and smaller projects, for example as pipe trace heating for the gutters of a production hall. In our range, you will find junction boxes, connection sets, end terminations, insulation entries, connectors and numerous other accessories.
Optimise the heating output in the long term
Trace heating end terminations
End terminations are vital components for reliably functioning trace heating. These components prevent moisture from penetrating into the heating cable and electrically insulate the end of the heating tape. In the Ziegler range, you will find heat-shrink and cold-connection end terminations, suitable for the intended plant or the selected cables. This plays a particularly important role when it comes to the increased requirements in hazardous areas. Our experts at ZIEGLER ENGINEERING answer all questions about the right trace heating end termination and other individual components.
Install heating tapes over long distances
Connectors for pipe trace heating
The ZIEGLER ENGINEERING range also includes connectors for heating tapes, whereby, for example, defective sections of heating tape need to be repaired and replaced. The key selection factor here is, once again, the coordination of the connector type with the selected system and the area of application. The ZIEGLER ENGINEERING range of accessories includes a large number of different connectors, including for challenging and safety-relevant applications, for example in hazardous areas. These allow reliable and permanently tight connections to be implemented without a hitch in most cases.
Would like some product advice?
Get in touch with our team of experts! Everything you get from ZIEGLER ENGINEERING is from a single source – from planning and commissioning through to maintenance of your electrical trace heating.
Optimise the heating output in the long term
Trace heating end terminations
End terminations are vital components for reliably functioning trace heating. These components prevent moisture from penetrating into the heating cable and electrically insulate the end of the heating tape. In the Ziegler range, you will find heat-shrink and cold-connection end terminations, suitable for the intended plant or the selected cables. This plays a particularly important role when it comes to the increased requirements in hazardous areas. Our experts at ZIEGLER ENGINEERING answer all questions about the right trace heating end termination and other individual components.
Ports, connectors and end terminations
Outstanding heating performance with accessories from ZIEGLER ENGINEERING
With over 50 years of experience, ZIEGLER ENGINEERING is the ideal partner for the planning and implementation of electrical trace heating projects. We deliver custom, one-stop solutions: a comprehensive range of high-quality accessories and components from connection boxes, connection sets and trace heating end terminations to different types of connectors and a wide variety of other products such as heating cables, heating tapes and thermostats, as well as a team of experts with the necessary expertise make us the top choice when it comes to planning and implementing your trace heating project. Benefit from our expertise in custom trace heating systems.
Thermal transfer solutions for every project

Thermostats and controllers
Thermostats and controllers ensure optimal control and regulation of pipe trace heating.

Heating cables
Our versatile range of heating cables ensures the right temperature and reliable frost protection outdoors.

Innovative special solutions
Custom trace heating solutions from ZIEGLER ENGINEERING for construction and special applications.
Frequently asked questions about components and accessories
Which components do I need for a heating circuit?
Which controllers are available for electrical trace heating?
To form a heating circuit you will need: a connection set, an end termination set, heating tape/heating cable, junction box and/or temperature controller and installation material such as glass silk tape.
Which controllers are available for electrical trace heating?
Centralised controllers can be installed in the control cabinet; decentralised controllers are placed on the pipeline/container. We also distinguish between ambient thermostats (measuring the ambient temperature) and direct line sensing, which directly measures the temperature of the object to be heated. Nowadays, many controllers can transmit information to control systems and receive information from said systems.
Which installation material is useful when it comes to trace heating?
Glass silk tape is usually used, but self-adhesive aluminium foil is also commonly used. This has a positive influence on heat transfer and increases the heat output of self-regulating heating tapes. In addition, it is primarily fixed resistance heating cables that can be mounted with straps, wires or wire mesh/wire baskets.
We provide support for your project
Get in touch with our team of experts
ZIEGLER ENGINEERING is your partner when it comes to electrical trace heating. We offer a wide range of products, vast experience and sound expert knowledge.